Rugi-rugi Daya pada Transformator U.019 PT. PLN 9persero) WS@JB Rayon Ampera Akibat Ketidakseimbangan Beban
DOI:
https://doi.org/10.31851/ampere.v3i1.3475Keywords:
load imbalance, Distribution transformer, load balanceAbstract
Power losses in distribution transformers can cause neutral currents. Neutral currents in distribution transformers can be caused by load imbalances. This study investigates the load imbalance on the secondary side of the transformer U.019 PT. PLN (PERSERO) Palembang Ampera Rayon. Measurement results and calculations show that if a neutral current load is equalized and power losses due to load imbalance in the distribution transformer are reduced. Unbalanced expense loss due to the neutral current of Peak Expense of 41,5090A and the lowest Expense of 12,1244A so that the percentage of loss in Peak Load loss is 5,3443% and the lowest expense is 1,8562%, and due to the falling unbalanced load voltage is obtained Percentage of Peak Loads of 7.28365% and Lowest Load of 2.43736% of balanced load loss due to neutral currents at balanced load, At Peak Load of 4.9482% and afternoon of 1.7647% and due to balanced load voltage drop in Peak can be 4,94819% and the lowest load can be 1,76471%. The load equalization results in the average peak load that is 262.66667 A with the current load current is IR 262A, IS 263A and IT 263A and at the lowest load average current is 95.0000 A, with a perfect load current IR 94 A, IS 95 A and IT 95 A. Difference Between Unbalanced Charges due to neutral currents with a balanced load at peak loads of 3.961% and the lowest load of 915% while the difference in the voltage drop is unbalanced and balanced at peak load 2.33546% and the Lowest Load amounting to 0.67265%
Â
ABSTRAK Rugi-rugi daya pada transformator distribusi dapat menimbulkan arus netral. Arus netral pada transformator distribusi dapat disebabkan ketidak seimbangan beban. Penelitian ini menyelidiki ketidakseimbangan beban pada sisi sekunder transformator U.019 PT. PLN (PERSERO) Rayon Ampera Palembang. Hasil pengukuran dan perhitungan menunjukkan bahwa apabila dilakukan pemerataan beban arus netral dan rugi – rugi daya akibat ketidakseimbangan beban pada transformator distribusi berkurang. rugi rugi beban ketidak seimbang akibat arus netral Beban Puncak sebesar 41,5090A dan Beban terendah sebesar 12,1244A sehingga persentase rugi rugi daya Beban Puncak sebesar 5,3443% dan beban Terendah 1,8562% ,dan akibat jatuh tegangan beban ketidak seimbang di peroleh persentase pada Beban Puncak Sebesar 7,28365% dan Beban Terendah 2,43736% rugi rugi beban seimbang akibat arus netral pada beban seimbang, Pada Beban Puncak sebesar 4,9482% dan siang 1,7647% dan akibat jatuh tegangan beban seimbang Benan Puncak di dapat 4,94819% dan Beban Terendah di dapat 1,76471%. Hasil pemerataan beban di dapat arus rata rata Beban Puncak yaitu 262,6667 A dengan arus beban perfasa yaitu IR 262A , IS 263A dan IT  263A dan pada beban Terendah arus rata rata yaitu 95,0000 A ,dengan arus beban perfasa yaitu IR 94 A , IS 95 A dan IT 95 A. Selisih Antara Beban Tidak Seimbang akibat arus netral dengan beban seimbang pada beban puncak sebesar 3,961% dan beban Terendah sebesar 915% sedangkan selisih pada jatuh tegangan tidak seimbang dan seimbang pada beban puncak 2,33546% dan Beban Terendah sebesar 0,67265%
Â
Kata kunci: ketidak seimbangan beban, pemerataan beban ,Transformator distribusi
References
Abdul Kadir, Transformator, Jakarta: PT. ElexMedia Komputindo, 1989.
Badaruddin, MT.2012. Pengaruh Ketidakseimbangan Beban Terhadap Arus Netral Dan
Losses Pada Trafo Distribusi Proyek Rusunami Gading Icon. Laporan Penelitian Internal
Universitas Mercu Buana
Kawihing Aprilian P., Tuegeh Maickel, St, Mt,Dkk.2013. Pemerataan Beban
Transformator Pada Saluran Distribusi Sekunder. Jurusan Teknik Elektro-Ft, Unsrat
Sudaryatno Sudirham,1991. Pengaruh Ketidakseimbangan Arus Terhadap Susut Daya
pada Saluran, Bandung: ITB, Tim Pelaksana Kerjasama PLN-ITB.
Sentosa Setiadji Julius, Machmudsyah Tabrani, Isnanto Yanuar .2006. Pengaruh
Ketidakseimbangan Beban Terhadap Arus Netral Dan Losses Pada Trafo Distribusi:
Surabaya
Moelyono W. Nono. Pengantar Sistem Distribusi Tenaga Listrik, Surabaya:
Jurusan Teknik Elektro, Fakultas Teknologi Industri, ITS, 1999, p.120
Downloads
Published
How to Cite
Issue
Section
License
Jurnal Ampere is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.