Proteksi Overload Motor Universal pada Alat Pengayakan Ulat Hongkong Menggunakan Thermal Overload Relay
DOI:
https://doi.org/10.31851/ampere.v10i1.16710Keywords:
Motor Universal, Thermal Overload Relay, Ulat Hongkong, Proteksi OverloadAbstract
The rapid growth of pet breeding, such as birds, hamsters, and ornamental fish, has driven the demand for
high-quality feed to support productivity. One commonly used feed is mealworms, whose screening process is still performed manually. To improve efficiency, an automatic screening tool utilizing a universal motor is required. However, continuous use of the motor can lead to damage due to overload, triggering an increase in current (overcurrent) and a rise in motor temperature. This study aims to protect the universal motor in the mealworm screening machine from overload and excessive temperature increases. The trials were conducted three times, each with five repetitions. The first trial was performed without a load, the second with a constant mealworm load of 4000 grams, and the third with a constant load of 6500 grams. The analysis results indicate that the greater the load borne by the motor, the higher the current and power required. The recommended maximum current for optimal motor operation is 2.2 A, with a maximum load of 4000-5000 grams. Overload protection is essential to prevent motor damage and ensure the screening machine operates efficiently and has a longer service life.
References
A. Daud, J. Teknik, and K. Energi, “Rancang Bangun Modul Proteksi Arus Beban Lebih dan Hubung Singkat,” 2019.
D. G. P. L. Hapsari, A. M. Fuah, and Y. C. Endrawati, “Produktivitas Ulat Hongkong (Tenebrio molitor) pada Media Pakan yang Berbeda Productivities of Tenebrio larva (Tenebrio molitor) in Different Feeding Media,” 2018.
Mk. Amri Rosa and I. Novia Anggraini, “Sistem Proteksi Motor Induksi 3 Fasa Terhadap Bermacam Gangguan Menggunakan Mikrokontroller,” Jurnal Amplifier Mei, vol. 10, no. 1, 2020.
M. Sarifatullah, D. Notosudjono, and D. Suhendi, “Perancangan Sistem Proteksi Thermal pada Motor Induksi 3 Fasa Berbasis Kontrol Arduino Menggunakan Jaringan IoT,” 2020.
Tiyono, “Perancangan Setting rele Proteksi Arus Lebih pada Motor Listrik Industri.”
N. Indrihastuti, A. Prayoga, and M. A. Musyaffa, “Perancangan Kendali 2 Kontaktor Bekerja Berurutan Secara Otomatis Berbasis PLC CPM1A 40CDR_A.” [Online]. Available: https://jurnal.umpp.ac.id/index.php/cahaya_bagaskara/
T. Puspita and I. Akbar Darmawan, “Thermal Overload Relay (TOR) Sebagai Sistem Proteksi Motor Induksi 3 Fasa Pada Mesin Molding Biofuel Pelletizer Di PT. Sejin Lestari Furniture,” JTMEI), vol. 2, no. 2, pp. 168–181, 2023, doi: 10.55606/jtmei.v2i2.1773.
akhwan, A. Pradipta, and B. Gunari, “Rancang Bangun Simulator Perbaikan Faktor Daya Listrik 3 Fasa dengan Sistem Kendali Otomatis,” Jurnal Arus Elektro Indonesia (JAEI).
R. Yusuf Lubis, L. Husna Lubis, dan Miftahul Husnah, and P. Studi Fisika Fakultas Sains dan Teknologi UIN Sumatera Utara Medan, “Pengaruh Variasi Suhu Terhadap Nilai Hambatan pada Rangkaian Listrik,” 2020.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Sofiah Sofiah, dila husna, M Arafat

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Jurnal Ampere is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.